摘要:

针对目前国内自主研制超声导波检测设备能力不足以及常规超声导波检测灵敏度较低等问题,构建一种基于改进时间反转法的超声导波检测系统。利用超声导波线性叠加性,单独激励时间反转信号,再线性叠加检测信号,在LabVIEW环境下,开发基于NEXTKIT信号万用仪和NI PXI-6331采集卡的超声导波时间反转检测系统。实验结果表明:纯净的时间反转信号是获得良好聚焦效果的前提,为窗宽选择提供依据,有效提高小缺陷反射回波信号幅值,为设备小型化提供可能。


Establish ultrasonic guided wave testing system based on improved method of time reversal

WANG Jian-bin1, DU Yun-peng1, ZHANG Xuan-shuo1,2

1. Ordnance Engineering College, Shijiazhuang 050003, China;
2. The Nanjing Military Representative Office, Nanjing 210008, China

Abstract: For the lack of capacity for developing ultrasonic guided wave detection equipment independently in the domestic and the low sensitivity of conventional ultrasonic guided wave detection, the authors constructed an ultrasonic guided wave detection system based on improved time reversal method. The characteristic of ultrasonic guided wave linear superposition is used, and then the improved method of linear superposition signal detection is also used. In this article, by utilizing the NEXTKIT universal instrument and NI PXI-6331 data acquisition card, a system of ultrasonic guided wave by time reversal was designed in the environment of LabVIEW. The results of experiment by encouraging time reversal signal with different width of windows show that pure time reversal signal is the precondition to enhance the detection results, and provides the basis to choice the width of window. The system can enhance the resolution of echo and provide the possibility for the miniaturization for the equipment.

Keywords: ultrasonic guided wave; time reversal; linear superposition; flaws

2014, 40(2): 130-134  收稿日期: 2013-6-29;收到修改稿日期: 2013-8-23

基金项目: 

作者简介: 王建斌(1967-),男,河北保定市人,副教授,硕士,主要从事智能信息化处理、无损检测研究。

参考文献

[1] Mathias F. Time reversal of ultrasonic fields-part I:Basic principles[J]. IEEE Transaction on Ultrasonic,Ferroelectrivs and Frequency Control,1992,39(5):555-566.
[2] Francois W, Jean L T, Mathias F. Time reversal of ultrasonic fields-part II: Experimental results[J]. IEEE Transaction,1992,39(5):567-578.
[3] 李大勇,高桂丽,董静薇. 非线性声学和时间反转声学在材料缺陷识别中的应用现状评述[J]. 机械工程学报,2009,45(1):1-8.
[4] 张国垒,汤宝平,戴功伟. 面向机械参量的通用数据采集仪的设计[J]. 中国测试,2012,38(2):69-72.
[5] 吴斌,颜丙生. 非线性超声检测镁合金疲劳的仿真和试验[J].振动、测试与诊断,2012,32(1):96-100.
[6] 武健,郭永,侯占峰,等. 基于LabVIEW2010的发动机振动信号采集系统的开发与研究[J]. 中国测试,2012,38(5):95-97.
[7] 张健滔,姚志远,宋小刚,等. 基于虚拟仪器的直流超声电机机械特性测试[J]. 振动、测试与诊断,2012,32(2):218-222.
[8] 王丽. 基于LabVIEW技术的控制工程实验系统的设计[J].中国测试,2012,38(5):98-101.
[9] 吴星明. AD811视频运算放大器的主要技术性能及其应用[J]. 电子技术应用,1995(7):40-44.
[10] 夏晶,孙继银,李辉. 基于PXI总线的电子设备测试系统设计[J]. 仪器仪表学报,2007,28(4):311-314.
[11] 张海燕,孙修立,曹亚萍,等. 基于时间反转理论的聚焦Lamb波结构损伤成像[J]. 物理学报,2010,59(10):7111-7119.