摘要:

针对数字式超声探伤仪水平线性误差的准确测试,提出一种方法,即基于33250A型函数信号发生器,利用其函数信号发生器外部触发延时输出的功能模拟超声探伤仪水平线性的距离,可以准确地测试数字式超声探伤仪的水平线性误差。通过实验设计和实验数据验证,结果表明:该方法有效可行,可为超声探伤仪的水平线性误差测试提供参考。


Horizontal linear error test method for digital ultrasonic flaw detector based on 33250A signal generator

CHEN Shenli, HE Zhuobin, YANG Dejun

Guangdong Institute of Metrology, Guangzhou 510405, China

Abstract: A 33250A function signal generator is used to test accurate horizontal linear error of digital ultrasonic flaw detectors. First, the delay output triggered by the function signal generator is applied to simulate the horizontal linearity distance of the detector. Then, the horizontal linear error could be accurately tested according to the formula that distance is the product of time and speed. Eventually, this method is proved feasible through experimental design and data.

Keywords: ultrasonic flaw detector;scanning range;horizontal linear error;electrical signal

2016, 42(1): 38-40  收稿日期: 2015-07-17;收到修改稿日期: 2015-08-07

基金项目: 

作者简介: 陈沈理(1984-),男,广东广州市人,工程师,主要从事声学、振动等方面设备仪器的计量工作。

参考文献

[1] 丁兵,黄燕琳,金磊. 超声检测系统的检定和期间核查[J].造船技术,2014(4):44-49.
[2] 袁淑芳. 超声波探伤仪检定方法探讨[J]. 计量技术,2005(1):36-37.
[3] 马春,刘辉. 无损检测仪器检定和校准方法[J]. 计量与检测技术,2008(1):70-71.
[4] 夏纪真. 超声波探伤仪器的性能评定——中国和欧洲标准的比较[J]. 无损探伤,2006,30(5):27-30.
[5] Non-destructive testing-Characterization and verification of ultrasonic examination equipment-Part1:Instruments:EN 12668-1——2010[S]. 2010.
[6] 李克伟. 无损探伤仪检定方法研究及检定装置的研制[D].上海:上海交通大学,2007.
[7] 陈洪程. 超声探伤仪的检定[J]. 标准、质保与检测,2003,43(1):43-45.
[8] 超声探伤仪检定规程:JJG 746——2004[S]. 北京:中国计量出版社,2004.
[9] A型脉冲反射式超声探伤仪通用技术条件:ZB Y230——1984[S]. 1984.