摘要:

为研究光谱载体LiCl对ICP-OES法测定Pb、Mn的影响,通过测定在不同LiCl浓度、射频功率、观测高度、载气流量和进样量条件下谱线MnⅠ279.482 nm,MnⅠ403.075 nm,MnⅡ257.610 nm,MnⅡ259.372 nm,PbⅠ217.000 nm,PbⅠ283.306 nm,PbⅡ220.353 nm的净强度,得到了各谱线灵敏度的影响规律。证明LiCl是ICP-OES法测定Pb、Mn的良好光谱载体,LiCl增敏ICP-OES法测定地表水中Pb、Mn是可行的。


Impact of spectrum carrier lithium chloride on determining lead and manganese by ICP-OES

CHEN Jiang, YANG Xiao-hong, YE Min, HE Ye-bo, ZHANG Hai-bin

Huzhou Environmental Monitoring Center, Huzhou 313000, China

Abstract: In order to study the impact of spectrum carrier LiCl on determining lead and manganese by ICP-OES, the law of spectrum sensitivity changes was obtained by determining the spectrum net intensity of MnⅠ279.482 nm, MnⅠ403.075 nm, MnⅡ257.610 nm, MnⅡ259.372 nm, PbⅠ217.000 nm, PbⅠ283.306 nm and PbⅡ220.353 nm in different conditions. The conditions were obtained through changing the concentration of LiCl, RF Power, observation height, the flow of carrier gas and injection volume. LiCl was proved to be good spectrum carrier for determining lead and manganese by ICP-OES. It was proved to be feasible for determining lead and manganese in water with Lithium chloride as sensitizer by ICP-OES.

Keywords: LiCl; ICP-OES; Lead; Manganese; Atomic line; Ion line

2010, 36(2): 41-43  收稿日期: 2009-7-30;收到修改稿日期: 2009-10-17

基金项目: 浙江省科技厅重点科研社会发展项目(2006C23070)

作者简介: 陈江(1980-),男,浙江湖州市人,工程师,主要从事环境监测工作。

参考文献

[1] 赵爱红,王建华,宋志刚,等. ICP-AES法测定丹参中的镉和铅[J]. 光谱学与光谱分析,2006(11):2 137-2 139.
[2] 董利珍,祁世明,崔 军. ICP-AES法测定普碳钢及低合金钢中铝等23种元素[J]. 冶金分析,2001(5):27-30.
[3] 王 虹,沙德仁,李 勇,等. 电感耦合等离子体发射光谱法同时测定玻璃中的硫和磷[J].分析试验室,2007(1):112-115.
[4] 张秋月,郑国经. ICP-AES法测定高温合金中钽的研究[J].冶金分析,2005(4):25-29.
[5] 弓晓峰,陈春丽,赵 晋,等. 微波消解-ICP-AES测定鄱阳湖流域沉积物中微量元素[J].光谱学与光谱分析,2007(8):1 634-1 637.
[6] 陈新坤. 电感耦合等离子体光谱法原理和应用[M]. 天津:南开大学出版社,1987.
[7] Newman E J, Farrow R N. Application and problems of the inductively coupled plasma(ICP) in the chemical industry[J]. Proc. Anal. Div. Chem.,1978(15):311-315.
[8] 陈金忠,魏艳红,郭庆林,等. 光谱载体对激光光源等离子体中发射强度的增强效应[J].光谱学与光谱分析,1997,17(6):36-39.
[9] 辛仁轩. 等离子体发射光谱分析[M]. 北京:化学工业出版社,2004.