永磁发电机在离网型风电系统中运行特性的测试分析

2562    2016-01-18

免费

全文售价

作者:温彩凤1,3, 汪建文1,2, 代元军1,4, 刘雄飞1, 车飞1

作者单位:1. 内蒙古工业大学能源与动力学院, 内蒙古 呼和浩特 010051;
2. 内蒙古可再生能源重点实验室, 内蒙古 呼和浩特 010051;
3. 呼和浩特职业学院, 内蒙古 呼和浩特 010051;
4. 新疆工业高等专科学校, 新疆 乌鲁木齐 830091


关键词:永磁同步发电机; 离网型风力发电; 运行特性; 测试曲线; 最佳性能


摘要:

通过实验分析法,针对某400W风力发电的永磁同步发电机运行特性进行了测试和分析.为了能准确、有效地对发电机的特性参数进行综合测试,搭建了发电机特性综合测试系统平台,系统采取VVVF交交变频器自动控制的三相异步电动机直接驱动发电机的运转方式,并配备专业化的EDA9033G数据采集器和JW-1型扭矩仪,实现了对发电机电压、电流、频率、功率、转速、转矩等参数的实时监测、显示、存储等功能.依据实验所得数据,拟合了发电机空载特性、输出特性、效率特性、外特性及转矩特性曲线.通过分析各曲线,对该永磁同步发电机的性能做出了评价,并以提高离网型风电机组的风能捕获效率为依据,提出了永磁发电机应具有的最佳性能.


Testing and analysis on running characteristics of permanent magnet generator in off-grid wind power system

WEN Cai-feng1,3, WANG Jian-wen1,2, DAI Yuan-jun1,4, LIU Xiong-fei1, CHE Fei1

1. College of Energy and Power Engineering Inner Mongolia University of Technology, Hohhot 010051, China;
2. Inner Mongolia Key Laboratory of Renewable Energy, Hohhot 010051, China;
3. Hohhot Vocational College, Hohhot 010051, China;
4. Xinjiang Ploytechnical College, Urumqi 830091, China

Abstract: In view of a 400 watt wind power, the running characteristics of permanent magnet synchronous generator are tested and researched by the method of experiment analysis. In order to carry out the comprehensive testing of the generator's characteristics exactly and effectively, platform of comprehensive testing system of generator's characteristics are put up. This system uses the three-phase asynchronous motor which is automatically controlled by VVVF alternating frequency inverter to drive the generator directly, and installs professional EDA9033G data collector and JW-1 torque gauge, realizes the real-time monitoring, display and storage of generator voltage, current and frequency, power, speed, torque and other parameters, etc. The non-load characteristics of the generator, output characteristics, efficiency characteristic, the outer characteristic and torque characteristic curve were fitted separately with experimental data, and the performance of the permanent magnet synchronous generator is evaluated through analyzing these curves. Aimed at improving the wind catching efficiency of the off-grid wind generator, the authors propounded the best performance of the permanent magnetism generator.

Keywords: permanent magnet synchronous generator; Off-grid wind turbine; running characteristics; testing curve; best performance

2011, 37(5): 63-67  收稿日期: 2010-12-10;收到修改稿日期: 2011-2-24

基金项目: 内蒙古自然科学基金重点项目(20080404ZD15)

作者简介: 温彩凤(1980-), 女, 博士研究生, 主要从事风力发电机技术方面的研究.

参考文献

[1] 王晓港, 翟庆志, 杨德昌. 离网型风电系统的现状[J]. 新能源, 2008, 257(10): 46-47.
[2] 窦一平, 陈海镇.稀土永磁同步发电机外特性的向量法分析[J]. 南京航空航天大学学报, 1999, 31(3): 312-317.
[3] 唐任远. 现代永磁电机理论与设计[M]. 北京: 机械工业出版社, 2008, 1(5): 273-307.
[4] Arifujjaman M, Iqbal M T. Energy capture by a small wind-energy conversion system[J]. Applied Energy, 2008, 85(1): 41-45.
[5] 风力机械标准汇编: 2006/全国风力机械标准化技术委员会, 中国农机工业协会风力机械分会编[M]. 北京: 中国标准出版社, 2006, 11(1): 576-578.
[6] GB/T 19068.2—2003离网型风力发电机组试验方法[M].北京: 中国标准出版社, 2003.