作者:甘雄, 朱永, 章鹏, 陈伟民
作者单位:重庆大学光电技术及系统教育部重点试验室, 重庆 400044
关键词:光纤珐珀传感器; 应变; 安全监测; 桥梁结构; 傅里叶变换
摘要:
应变是表征桥梁安全状态的重要指标。依据光纤珐珀应变传感器的特点以及石板坡长江大桥的实际情况,设计出多通道光纤珐珀应变测量系统。该测量系统成功地实现了光纤、光电测量技术、计算机技术和土木工程技术的交叉融合,实现了大型连续桥梁应变自动测量。运行结果表明,该测量系统具有一定的可行性和可靠性。
Multi-channel fiber optical fabry-perot strain testing system for the shibanpo yangtze river bridge
GAN Xiong, ZHU Yong, ZHANG Peng, CHEN Wei-min
Key Laboratory, Optoelectronic Technology and System Education Ministry, Chongqing University, Chongqing 400044, China
Abstract: Structure strain is one of the important parameters of representing bridge safety condition. Multi-channel fiber optic Fabry-perot strain testing system were designed depending on situation of Shibanpo Yangtze River Bridge and characteristic of fiber optic Fabry-perot strain sensor. This system realized amalgamation of fiber, photoelectricity testing technology, computer technology and civil engineering technology, and realized strain autotesting of large-scale continuous bridge. The result indicates that this system has some feasibility and dependability.
Keywords: Fiber optical fabry-perot sensor; Strain; Safety monitoring; Bridge structure; Fourier transform
2008, 34(6): 128-130,140 收稿日期: 2007-4-18;收到修改稿日期: 2007-7-5
基金项目: 重庆市自然科学基金项目(7289-2)
作者简介: 甘雄(1981-),男,四川泸州市人,硕士研究生,专业方向为光纤传感技术。
参考文献
[1] 黄尚廉, 陶宝祺, 沈亚鹏.智能结构系统——梦想、现实与未来[J].机械工程, 2000, 11(1, 2):32-34.
[2] 黄尚廉.智能结构系统-减灾防灾的研究前沿[J].土木工程学报, 2000, 33(4):1-5.
[3] 朱永.光纤珐珀应变传感器应用基础研究[M].重庆:重庆大学出版社, 2000.
[4] Mathieu J P. OPTICS[M].Science Press, 1987.
[5] 章鹏, 朱永, 陈伟民.光纤法布里-珀罗传感器腔长的傅里叶变换解调原理研究[J]. 光子学报, 2004, 33(12):1449-1452.
[6] 陈伟民, 朱永, 唐晓初, 等.光纤法布里-珀罗传感器串联复用的傅里叶变换解调方法初探[J]. 光学学报, 2004, 24(11):1841-1846.
[7] 朱永, 陈伟民, 封君, 等.光纤珐珀应变传感系统的实验研究[J].土木工程学报, 2001, 34(5):24-28.
[8] 黄尚廉, 陈伟民, 饶云江, 等.光纤应变传感器及其在结构健康监测中的应用[J].测控技术, 2004, 23(5):1-4.