作者:王慧丽
作者单位:邯郸市自来水公司水质监测中心, 河北邯郸 056003
关键词:连续流动分析; 总氮; 水样; 磺胺; NEDD
摘要:
介绍了连续流动分析法测定水中总氮的过程,通过在线UV消化器,过硫酸钾被光分解为硫酸盐自由基。样品中无机和有机氮被硫酸盐自由基氧化为硝酸盐。硝酸盐被还原为亚硝酸盐,与磺胺/NEDD反应生成红色络合物在550nm下测定。此方法具有重现性好灵敏度高的特点。回收率为96%~103%相对标准偏差小于1.2%。
Determination of total nitride in water through on-line reaction of sulfanilamide/NEDD
WANG Hui-li
Water Quality Monitoring Center of Handan City Running Water Company, Handan 056003, China
Abstract: The process of total nitrie determination in water by on-line reaction was described in this paper.Persulphate was photo-degradated into kraft radical by on-line UV digestor,inorganic or/and organic nitride in sample was oxidated into nitrate by the kraft radical,and the nitrate would be reduced into nitrite.The red complex formed through reaction of nittrite and sulfanilamide/NEDD could be detected at 550nm.The recovery of this method is 96~103%,relative standard deviation(RSD) less than 1.2%,and its repeatability and sensitivity are very well.
Keywords: On-line analysis; Total nitride; Water sapmle; Sulfanilamide; NEDD
2007, 33(3): 131-132,135 收稿日期: 2006-12-15;收到修改稿日期: 2007-2-10
基金项目:
作者简介: 王慧丽(1971-),女,工程师,主要从事仪器分析及环境监测技术研究。
参考文献
[1] 魏复盛,寇洪茹,洪水皆,等.水和废水监测分析方法[M].北京:环境科学出版社,1988.
[2] 郭延红,等.流动注射安培法快速测定食盐中碘[J].理化检验(化学分册),2002,38(1):10-12.
[3] 杨万龙,李一峻,何锡文.光度分析[J].分析实验室,1999,18(2):89-91.
[4] 生活饮用水卫生规范[S].卫生部卫生法制与监督司,2001.
[5] 华中师范大学,东北师范大学,陕西师范大学.分析化学[M].北京:高等教育出版社,1980.